Datasheet

L.
36 MEASUREMENT PARAMETER SELECTIONS
The GDS-1000B series oscilloscope is equipped with 36 different
automatic measurement parameter functions. Users, after
obtaining measured waveforms, can select different measurement
parameters from Measure key according to different measurement
requirements. The GDS-1000B Series shows simultaneously eight
sets of different measurement parameters on the bottom of the
display screen. Users can also select to show all parameters if
the preset eight sets are insufficient. Once the selection is made,
all 36 measurement parameters will be shown on the center of
the display screen. This is a very convenient measurement tool
for students writing dissertations or engineers writing reports.
J.
DATA LOG FUNCTION
K.
DIGITAL FILTER FUNCTION
H. I.
GO/NOGO FUNCTION
DIGITAL VOLTAGE METER FUNCTION
For electric circuit measurement and debugging, R&D engineers
require oscilloscopes as well as basic voltage meters. The GDS-1000B
series oscilloscope equips with a digital voltage meter with three-digit
voltage value and five-digit frequency value. Engineers, by pressing
the option key, can select the digital voltage meter function from the
menu to measure DC/AC voltage, duty cycle, and frequency.
Engineers can not only measure waveforms but also monitor the
electric parameters of each component on the circuit board. The
function is a very convenient tool.
The GDS-1000B Series oscilloscope has the data log function option,
which allows users to observe and record waveform changes in a long
period of time to ensure product's reliability and stability. The data log
function can set data storage time and interval based on the test
requirements. Record time can be set from 5 minutes to 100 hours
and the interval can be set as 5 seconds the shortest. Data log formats
include waveform and point data in CSV file. Data can be saved to
USB, GDS-1000B or remote computer via LAN. It is very user-friendly
and also an advanced measurement management tool.
For the industries, the yield rate determination is very important to
mass production. The GDS-1000B series oscilloscope provides the
Go/NoGo analysis function to accelerate the yield rate analysis.
From the right diagram, the Go/NoGo function provides a standard
waveform template for examining DUT's waveforms. The function
can freely adjust the size of template. A defect message will be shown
if the DUT's waveform is abnormal and touches the template. The
function is not only very useful measurement tool for production lines
but also a very convenient tool for engineers to observe waveforms in
a long period of time.
* Users need to download this application from GW Instek website
* Users need to download this application from GW Instek website
* Users need to download this application from GW Instek website
In electric circuit tests, engineers are often troubled by noise
interference while measuring signals. The GDS-1000B series
oscilloscope provides the digital filter function option, which can
be set as high pass or low pass filter. The filter frequency can be
adjusted according to the requirements. The filter parameters of
each channel can also be set. The tracking on function can be
used to set same filter frequency for all channels.