Switch the Display Modes 
The ASR-2000 power supply has three display modes. The 
standard display mode shows the power supply setup in the 
middle and the 3 configurable measurements on the right that 
correspond to the far-left live-time measurements section. The 
simple display mode shows all measurement items available on the 
ASR-2000 with 3 measurement formats switchable at any time. The 
harmonic display mode shows both harmonic voltage and 
harmonic current relevant measurements for user. 
Steps 
1.  Press the Display key. 
2.  The display mode will toggle each 
time when the key is pressed 
besides locked mode. 
Standard Mode 
Measurement Setting
Configurable 
measurements
Hold 
measurement
Configuring the 
Standard Mode 
Measurements 
1.  Press the F1(ITEM1), F2(ITEM2) 
or F3(ITEM3) soft-key to enter 
each menu. 
2.  Use the scroll wheel to select a measurement 
item and press Enter to confirm. Refer to page 
89 for more details of measurement parameters. 