User Manual
  OPERATION 
79 
Setting the Output Current Level 
Background 
The IRMS and I settings set the current of the 
output. Setting the RMS or AVG current sets a 
limit on the current that can be sourced by the 
power supply. Once the output current is over 
the setting, the output will set to off. 
Steps 
1.  Press Irms to access the IRMS or I 
menu depending on varied modes. 
Also, it is available to use the 
scroll wheel followed by the Enter 
key to make the IRMS or I 
parameter selectable as well. 
2.  Set the IRMS/I level with the scroll wheel or 
with the F3 ~ F4 soft-keys. The MAX and MIN 
soft-keys set the IRMS or I level to the 
maximum and minimum, respectively.  
AC+DC-INT, AC–INT, DC-INT, AC+DC-EXT, 
AC–EXT, AC+DC-ADD, AC–ADD, AC+DC-
Sync, AC-Sync 
IRMS/
I 
Range 
5% ~ 105% of rate current 
Soft-keys 
IRMS Limit On/Off, MAX, 
MIN 
Example of IRMS 
Setting in the 
AC+DC-INT 
IRMS setting
Soft-keys setting
F3
F4
F1