User Manual
    ASR-2000 Series User Manual 
74 
Setting the Output Frequency & Signal 
Background 
The FREQ and SIN settings set the frequency of 
the output. Before setting the frequency, set the 
frequency limit. 
Steps 
1.  Press the F key to access the FREQ 
or SIG parameter depending on 
varied modes. 
Also, it is available to use the 
scroll wheel followed by the Enter 
key to make the FREQ or SIG 
parameter selectable as well. 
2.  Set the frequency or signal with the scroll 
wheel or with the F1 ~ F4 soft-keys. 
AC+DC-INT, AC+DC-ADD 
FREQ 
Range 
1.00 ~ 999.9 Hz 
Soft-keys 
DEF1, DEF2, MAX, MIN 
AC-INT, AC-ADD 
FREQ 
Range 
40.00 ~ 999.9 Hz 
Soft-keys 
DEF1, DEF2, MAX, MIN 
AC+DC-Sync, AC-Sync 
SIG 
Option 
LINE, EXT 
3.  Press Enter key to confirm the frequency or 
signal setting. 
Defined Settings 
The DEF1 and DEF2 settings are user defined 
settings. By default they are set to 50.00 Hz and 
60.00 Hz, respectively. The MAX and MIN soft-
keys set the frequency to the maximum and 
minimum, respectively. 