User Manual
    ASR-2000 Series User Manual 
24 
Theory of Operation 
The theory of operation chapter describes the basic principles of 
operation, protection modes and important considerations that 
must be taken into account before use. 
Description of ASR-2000 System 
System block are composed of the parts described below. 
  Input EMI Filter 
and PFC Circuit 
A two stage π filter and a passive PFC circuit 
that convert AC power to DC power. 
  Auxiliary Power 
It converts AC power line input to +24Vdc 
power for the PWM ICs, fan, among other 
devices. 
  Isolation DC to 
DC Converter 
The isolation DC to DC converter is able to 
convert high DC level to lower that not only 
offers inverter a stable DC source but separates 
primary and secondary side efficiently. 
  Output Power 
Stage (inverter) 
Two inverter power stages are in parallel or in 
series that provide, in addition to AC and DC 
output, sinusoid, square as well as triangle 
output waveforms. 
  Digital 
Processor and 
Close Loop 
Control Circuit 
Composition of the C2000 DSP device and the 
closed-loop control circuit that execute inverter 
action, output measurement and all of the 
relevant protection functions. 
  Communication 
Interface and 
Data 
Transmission 
DSP, FPGA and LCD controller that are 
collectively responsible for interface 
communication, data transmission, LED panel 
control as well as remote control. 
  Keypad and 
Display 
CPLD that controls keys action and 
communicates with DSP for data transmission. 