User Manual
  APPENDIX 
197 
Harmonic voltage 
Effective value (rms) 
Percent (%) 
(AC-INT and 50/60 
Hz only)   
Range 
Up to 40th order of the fundamental wave 
Full Scale 
175 V / 350 V, 100% 
Resolution 
0.1 V, 0.01% 
Accuracy*8 
Up to 20th 
±(0.2 % of reading + 0.5 V / 1 V) 
20th to 40th 
±(0.3 % of reading + 0.5 V / 1 V) 
Harmonic current 
Effective value (rms) 
Percent (%) 
(AC-INT and 50/60 
Hz only) 
Range 
Up to 40th order of the fundamental wave 
Full Scale 
5 A / 2.5 A, 100% 
10 A / 5 A, 100% 
Resolution 
0.01 A, 0.01% 
Accuracy*3 
Up to 20th 
±(1 % of reading + 
0.1 A / 0.05 A) 
20th to 40th 
±(1.5 % of reading + 
0.1 A / 0.05 A) 
Up to 20th 
±(1 % of reading + 
0.2 A / 0.1 A) 
20th to 40th 
±(1.5 % of reading + 
0.2 A / 0.1 A) 
*1 
The voltage display is set to RMS in AC/AC+DC mode and AVG in DC mode  
*2 
AC mode: For an output voltage of 17.5 V to 175 V / 35 V to 350 V and 23 °C ± 5 °C. 
DC mode: For an output voltage of 25 V to 250 V / 50 V to 500 V and 23 °C ± 5. 
*3 
An output current in the range of 5 % to 100 % of the maximum current, and 23 °C ± 5 °C. 
*4 
An output current in the range of 5 % to 100 % of the maximum peak current in AC 
mode, an output current in the range of 5 % to 100 % of the maximum instantaneous 
current in DC mode, and 23 °C ± 5 °C. The accuracy of the peak value is for a 
waveform of DC or sine wave         
*5 
For an output voltage of 50 V or greater, an output current in the range of 10 % to 100 % 
of the maximum current, DC or an output frequency of 45 Hz to 65 Hz, and 23 °C ± 5 °C. 
*6 
The apparent and reactive powers are not displayed in the DC mode.   
*7 
The reactive power is for the load with the power factor 0.5 or lower.   
*8 
An output voltage in the range of 17.5 V to 175 V / 35 V to 350 V and 23 °C ± 5 °C. 
Note: 
  Product specifications are subject to change without notice. 