User Manual
    ASR-2000 Series User Manual 
196 
*2 
For an output voltage of 100 V / 200 V, a load power factor of 1, with respect to 
stepwise change from an output current of 0 A to the maximum current (or its 
reverse). 10% ~ 90% of output voltage 
*3 
For AC mode, at an output voltage of 100 V / 200 V, maximum current, and load power 
factor of 1 and sine wave only. 
Model 
ASR-2050 
ASR-2050R 
ASR-2100 
ASR-2100R 
Measured value display 
Note: 
All accuracy of the measurement function is indicated for 23 °C±5 °C. 
Voltage 
RMS, AVG 
value*1 
Resolution 
0.1 V 
Accuracy*2 
For 45 Hz to 65 Hz and DC: ±(0.5 % of 
reading + 0.3 V / 0.6 V) 
For 40 Hz to 999.9 Hz: ±(0.7 % of reading + 
0.9 V / 1.8 V) 
PEAK value 
Resolution 
0.1 V 
Accuracy 
For 45 Hz to 65 Hz and DC: ±(|2 % of 
reading| + 1 V / 2 V) 
Current 
RMS, AVG 
value 
Resolution 
0.01 A 
Accuracy*3 
For 45 Hz to 65 Hz 
and DC: 
±(0.5 % of reading + 
0.02 A / 0.02 A) 
For 40 Hz to 999.9 
Hz: 
±(0.7 % of reading + 
0.04 A / 0.04 A) 
For 45 Hz to 65 Hz 
and DC: 
±(0.5 % of reading + 
0.04 A / 0.02 A) 
For 40 Hz to 999.9 
Hz: 
±(0.7 % of reading + 
0.08 A / 0.04 A) 
PEAK value 
Resolution 
0.1 A 
Accuracy*4 
For 45 Hz to 65 Hz 
and DC: 
±(|2 % of reading| + 
0.2 A / 0.1 A) 
For 45 Hz to 65 Hz 
and DC: 
±(|2 % of reading| + 
0.2 A / 0.1 A) 
Power 
Active (W) 
Resolution 
0.1 / 1 W 
Accuracy*5 
±(2 % of reading + 
0.5 W) 
±(2 % of reading + 1 
W) 
Apparent 
(VA) 
Resolution 
0.1 / 1 VA 
Accuracy*5
*6 
±(2 % of reading + 
0.5 VA) 
±(2 % of reading + 1 
VA) 
Reactive 
(VAR) 
Resolution 
0.1 / 1 VAR 
Accuracy*5
*7 
±(2 % of reading + 
0.5 VAR) 
±(2 % of reading + 1 
VAR) 
Load power factor   
Range 
0.000 to 1.000 
Resolution 
0.001 
Load crest factor   
Range 
0.00 to 50.00 
Resolution 
0.01 