Sensing Voltage Error 
Remote sense connection wire is 
abnormal or over maximum 
compensation voltage. Press 
"Shift + Cancel" to clear this 
alarm. 
Output Off 
Startup Anomaly 
Abnormal startup procedure. 
Contact service center. 
System Lock 
External Sync 
Frequency Error 
The external synchronization 
signal input frequency is out of the 
allowance range. (40Hz ~ 
999.9Hz) 
Output Off 
SCPI Error 
Communication with the SCPI 
command error 
Display Message 
Only 
Power ON Fail 
Power ON Function Fail In Error 
Mode or Range 
IRMS Limit 
The RMS current limiter is 
activated. Press "Irms" to check 
allowance set range 
IPK Limit 
The peak current limiter is 
activated. Press " Shift + Irms" to 
check allowance set range 
Remote Sensing 
Voltage Out of Range 
The Sensing voltage limiter is 
activated. 
Display Message 
Only 
System Error (#) 
System Error (1~15). Contact 
service center. 
Display Message 
Only 
 Note 
The system would be locked or output off automatically before the 
error state is cleared. 
Normal Messages 
Description 
Protection type 
Setting Voltage 
Limited 
Setting voltage be limited, press 
"Shift + V" to check allowance set 
range 
Display Message 
Only 
Setting Frequency 
Limited 
Setting frequency be limited, press 
"Shift + F" to check allowance set 
range 
Display Message 
Only 
Keys Locked 
All of keys are locked, except 
output key. Long push “Lock” to 
disable Keys Locked. 
Display Message 
Only 
Keys Unlocked 
All of keys are unlocked 
Display Message 
Only 
Screen Saved 
Screenshot be saved to USB 
memory successful 
Display Message 
Only 