User Manual
  APPENDIX 
183 
Factory Default Settings 
The following default settings are the factory configuration settings 
for the ASR-2000 series. For details on how to return to the factory 
default settings, see page 46. 
AC+DC-INT Mode 
ASR-2050 
ASR-2050R 
ASR-2100 
ASR-2100R 
Range 
100V 
Wave Shape 
SIN 
ACV 
0.0 Vrms 
DCV 
+0.0 Vdc 
FREQ 
50.00 Hz 
IRMS 
5.25 A 
10.50 A 
V Limit 
+/- 250.0 Vpp 
F Limit Lo 
1.0 Hz 
F Limit Hi 
999.9 Hz 
IPK Limit 
+/- 21.00 A 
+/- 42.00 A 
ON Phs 
0.0
o
OFF Phs 
0.0
o
AC-INT Mode 
ASR-2050 
ASR-2050R 
ASR-2100 
ASR-2100R 
Range 
100V 
Wave Shape 
SIN 
ACV 
0.0 Vrms 
FREQ 
50.00 Hz 
IRMS 
5.25 A 
10.50 A 
V Limit 
175.0 Vrms 
F Limit Lo 
40.0 Hz 
F Limit Hi 
999.9 Hz 
IPK Limit 
+/- 21.00 A 
+/- 42.00 A 
ON Phs 
0.0
o
OFF Phs 
0.0
o
DC-INT Mode 
ASR-2050 
ASR-2050R 
ASR-2100 
ASR-2100R 
Range 
100V 
DCV 
0.0 Vdc 
I 
5.25 A 
10.50 A 
V Limit 
+/- 250.0 Vpp 
IPK Limit 
+/- 21.00 A 
+/- 42.00 A 