Interface Configuration 
Configure Ethernet Connection 
The Ethernet interface can be configured for a number of different 
applications. Ethernet can be configured for basic remote control or 
monitoring using a web server or it can be configured as a socket 
server.  
The ASR-2000 supports both DHCP connections so the instrument 
can be automatically connected to an existing network or 
alternatively, network settings can be manually configured.  
Ethernet 
Parameters 
MAC Address 
(display only) 
DHCP 
IP Address 
Subnet mask 
Gateway 
DNS address 
DNS Server 
Socket port fixed at 2268 
Ethernet 
Configuration 
1.  Connect a LAN cable from the PC 
to the Ethernet port on the rear 
panel. 
LA
2.  Press the Menu key. The Menu 
setting will appear on the display. 
3.  Use the scroll wheel to go to item 3, LAN and 
press Enter. 
4.  If the LAN cable is installed correctly a 
connection is active, the Connection Status will 
show Online. 
5.  To automatically have the network assign an 
IP address, set DHCP to ON. Otherwise set 
DHCP to OFF to manually set the Ethernet 
settings. 