User Manual
  TEST MODE FUNCTION 
137 
13. Go to the Branch 1/2 setting and set a step to 
branch to. 
Branch 1, 2 
ON, OFF, 0 ~ 999 
14. Go to the Term setting and set the step 
termination setting. CONTI will automatically 
go to the next step at the end of the step. END 
will return to step 0. HOLD will stay at the 
current step until you allow the sequence to 
continue to the next step. 
Term 
CONTI, END, HOLD 
15. Go to the Sync Code setting and set the 
synchronous code when the step has started.  
Sync Code 
LL, LH, HL, HH 
16. Go to the ON Phs setting and set the starting 
phase of the step. The Fixed indicates user-
defined degree. 
ON Phase 
Free, Fixed 
ON Phase 
0.0 ~ 359.9º 
Resolution 
0.1º 
17. Go to the OFF Phs setting and set the end 
phase of the step. The Fixed indicates user-
defined degree. 
OFF Phase 
Free, Fixed 
OFF Phase 
0.0 ~ 359.9º 
Resolution 
0.1º 