Slew Rate Mode 
The slew rate, which is described as the fluctuating change of 
voltage per unit of time, can be customized by user in the 2 modes 
containing Time and Slope elaborated below for ASR-2000 models. 
Steps 
1.  Press the Menu key. The Menu 
setting will appear on the display. 
2.  Use the scroll wheel to go to item 2, MISC 
Configuration and press Enter. 
3.  Go to the Slew Rate Mode setting using the 
scroll wheel and press Enter. Choose the slew 
rate mode and press Enter again to confirm. 
Time 
Regardless of the output voltage scale, 
the rising time of slew rate is definitely 
no more than 100us. 
Slope 
The rising slew rate is constantly fixed in 
1.5 V/us with varied rising time in 
accord with differed output voltage scale. 
Exit 