Datasheet

Extended Universal Power Socket(ASR-2000R only)
Extended European Power Socket(ASR-2000R only)
ACCESSORIES
FREE DOWNLOAD
CD ROM(User Manual, Programming manual), Safety Guide, Power Cord,
Mains Terminal Cover Set, Remote Sense Terminal Cover Set, GTL-123 Test Lead,
GTL-246 USB Cable
Rack Mount Kit (EIA)
Rack Mount Kit (JIS)
RS-232C Cable, approx. 2M
GPIB Cable, approx. 2M, including
25 pins Micro-D connector
GET-003
GET-004
GRA-439-E
GRA-439-J
GTL-232
GTL-258
ASR-001
Air inlet filter
USB Driver
OPTIONAL ACCESSORIES
ORDERING INFORMATION
Opt01 : RS-232+GPIB Communication Functions(Factory installed)
Opt02 : European Output Outlet only for ASR-2000(Factory installed)
ASR-2050
500VA Programmable AC/DC Power Source
ASR-2100
1000VA Programmable AC/DC Power Source
ASR-2050R
500VA Programmable AC/DC Power Source for 3U 1/2 Rack Mount
ASR-2100R
1000VA Programmable AC/DC Power Source for 3U 1/2 Rack Mount
MAC Address, DNS IP Address, User Password, Gateway IP Address, Instrument IP Address, Subnet Mask
*1. The voltage display is set to RMS in AC/AC+DC mode and AVG in DC mode.
*2. AC mode: For an output voltage of 17.5 V to 175 V / 35 V to 350 V and 23 °C ± 5 °C. DC mode: For an output voltage of 25 V to 250 V / 50 V to 500 V and 23 °C ± 5 °C.
*3. An output current in the range of 5 % to 100 % of the maximum current, and 23 °C ± 5 °C.
*4. An output current in the range of 5 % to 100 % of the maximum peak current in AC mode, an output current in the range of 5 % to 100 % of the maximum instantaneous current in DC mode,
and 23 °C ± 5 °C. The accuracy of the peak value is for a waveform of DC or sine wave
*5. For an output voltage of 50 V or greater, an output current in the range of 10 % to 100 % of the maximum current, DC or an output frequency of 45 Hz to 65 Hz, and 23 °C ± 5 °C.
*6. The apparent and reactive powers are not displayed in the DC mode.
*7. The reactive power is for the load with the power factor 0.5 or lower. *8. An output voltage in the range of 17.5 V to 175 V / 35 V to 350 V and 23 °C ± 5 °C.
ASR-2000GD1BH
Specifications subject to change without notice.
Up to 20th ± (1 % of reading + 0.2 A / 0.1 A);
20th to 40th ± (1.5 % of reading + 0.2 A / 0.1 A)
OCP, OTP, OPP, FAN Fail
TFT-LCD, 4.3 inch
10 sets for Store and Recall settings
16 (nonvolatile)
4096 words
Type A: Host, Type B: Slave, Speed: 1.1/2.0, USB-CDC
External Signal Input; External Control I/O
SCPI-1993, IEEE 488.2 compliant interface
Complies with the EIA-RS-232 specifications
500 Vdc, 30 M or moreΩ
1500 Vac, 1 minute
EN 61326-1 (Class A)
EN 61326-2-1/-2-2 (Class A)
EN 61000-3-2 (Class A, Group 1)
EN 61000-3-3 (Class A, Group 1)
EN 61000-4-2/-4-3/-4-4/-4-5/-4-6/-4-8/-4-11 (Class A, Group 1)
EN 55011 (Class A, Group1)
EN 61010-1
Indoor use, Overvoltage Category II
0 °C to 40 °C
-10 °C to 70 °C
20 %rh to 80 % RH (no condensation)
90 % RH or less (no condensation)
Up to 2000 m
ASR-2000 : 285(W)×124(H)×480(D) (not including protrusions); Approx. 11.5 kg
ASR-2000R : 213(W)×124(H)×480(D) (not including protrusions); Approx. 10.5 kg
PROTECTIONS
DISPLAY
MEMORY FUNCTION
ARBITRARY WAVE
Number of Memories
Waveform Length
OTHERS
INTERFACE
USB
LAN
EXT Control
Factory Optional
GPIB
RS-232C
INSULATION RESISTANCE
Between input and chassis, output and chassis, input and output
WITHSTAND VOLTAGE
Between input and chassis, output and chassis, input and output
EMC
Safety
Environment Operating Environment
Operating Temperature Range
Storage Temperature Range
Operating Humidity Range
Storage Humidity Range
Altitude
DIMENSIONS & WEIGHT
Standard
Full Scale
Resolution
Accuracy
*3
5 A / 2.5 A, 100% 10 A / 5 A, 100%
0.01 A, 0.01% 0.01 A, 0.01%
Up to 20th ± (1 % of reading + 0.1 A / 0.05 A);
20th to 40th ± (1.5 % of reading + 0.1 A / 0.05 A)
EFFECTIVE VALUE (RMS)
PERCENT (%)
(AC-INT and 50/60 Hz only)
Resolution
Accuracy
*8
Range
0.1 V, 0.01% 0.1 V, 0.01%
Up to 20th ± (0.2 % of reading + 0.5 V / 1 V);
20th to 40th ± (0.3 % of reading + 0.5 V / 1 V)
Up to 20th ± (0.2 % of reading + 0.5 V / 1 V);
20th to 40th ± (0.3 % of reading + 0.5 V / 1 V)
Up to 40th order of the fundamental wave Up to 40th order of the fundamental wave
PERCENT (%)
(AC-INT and 50/60 Hz only)
HARMONIC CURRENT
SPECIFICATIONS
Range
Full Scale
Up to 40th order of the fundamental wave Up to 40th order of the fundamental wave
175 V / 350 V, 100% 175 V / 350 V, 100%
HARMONIC VOLTAGE
EFFECTIVE VALUE (RMS)
ASR-2100/ASR-2100RASR 2050/ASR-2050R-