Datasheet
SIMULATE MODE
G.
E.
REMOTE SENSE FUNCTION
T, IPK HOLD & IPK, HOLD FUNCTIONS
Simulate Mode can quickly simulate different transient
waveforms, such as power outage, voltage rise, voltage fall, etc.,
For high current output applications, the voltage drop caused by
large current passing through the load cables will affect the
measurement results. The ASR-2000 series provides the remote
sense function that can sense the voltage drop of the DUT to the
ASR-2000 series and the DUT will be compensated by the ASR-2000
series. The maximum voltage that the remote sense function can
compensate is 5% of the output voltage.
T, Ipk Hold is used to set the delay time after the output (1ms ~
60,000ms) to capture the Ipeak value and keep the maximum
value. The update only functions when the measurement value
is greater than the original value. The T, Ipk Hold delay time
setting can be used to measure surge current at the power on
process of the DUT.
Ipk Hold can be used to measure the transient surge current of
the DUT at power on without using an oscilloscope and a
current probe.
for engineers to evaluate the impact of transient phenomena
on the DUT. Ex: Capacitance durability test.
The ASR-2000 series can set the Slew Rate Mode to determine the
rise time of the voltage according to the test requirements of the
DUT. Slew Rate Mode provides "Time" and "Slope" modes. When
setting "Time" mode, ASR-2000 can increase output to 10~90% of
the set voltage within 100 s; and when selecting "Slope" mode,μ
ASR-2000 increases output voltage by a fixed rising slope of
1.5V/ s until reaching the set voltage value.μ
In addition, if users decide to self-define the rise time of the
output voltage, users can flexibly set the rise time of the ASR-2000
series voltage by editing the Sequence mode.
Power Outage
T, Ipk Measurement
Voltage Rise
Voltage Fall
F.
SLEW RATE MODE
Time Mode Slope Mode
D.
SIMULATE MODE