Datasheet

PANEL INTRODUCTION
1. Air Inlet
2. LCD Screen
3. Display Mode Select Key
4. Function Keys
5. Scroll Wheel
6. Output Key
7. Hardcopy Key
LAN
Ext I/O
10
5
5
1
1
3
3
2
2
11
15
15
14
14
16
16
18
18
19
19
12
12
13
13
17
17
4
4
15. Output Terminal
16. Line Input
17. External Signal Input/External
Synchronized Signal Input
18. RS-232C & GPIB Connectors
19. LAN Connector
20. USB Interface Connector(B Type)
20
20
6
6
9
7
7
8
8
10
9
8. Lock/Unlock Button
9. USB Interface Connector(A Type)
10. Power Switch Button
11. Output Socket
12. External I/O Connector
13. Exhaust Fan
14. Remote Sensing Input Terminal
The ASR-2000 series, an AC+DC power source aiming for system integration or desktop applications, provides both rated power output
for AC output and rated power output for DC output. Nine ASR-2000 output modes are available, including 1) AC power output mode
(AC-INT Mode), 2) DC power output mode (DC-INT Mode), 3) AC/DC power output mode (AC+DC-INT Mode), 4) External AC signal
source mode (AC-EXT Mode), 5) External AC/DC signal source mode (AC+DC-EXT Mode), 6) External AC signal superposition mode
(AC-ADD Mode), 7) External AC/DC signal superposition mode (AC+DC-ADD Mode), 8) External AC signal synchronization mode (AC-
SYNC Mode), 9) External AC/DC signal synchronization mode (AC+DC-SYNC Mode).
The ASR-2000 series provides users with waveform output capabilities to meet the test requirements of different electronic component
development, automotive electrical devices and home appliance, including 1) Sequence mode generates waveform fallings, surges, sags,
changes and other abnormal power line conditions; 2) Arbitrary waveform function allows users to store/upload user-defined
waveforms; and 3) Simulate mode simulates power outage, voltage rise, voltage fall, and frequency variations. When the ASR-2000 series
power source outputs, it can also measure Vrms, Vavg, Vpeak, Irms, Iavg, Ipeak, IpkH, P, S, Q, PF, CF, 40th-order Voltage Harmonic and
Current Harmonic. In addition, the Remote sense function ensures accurate voltage output. The Customized Phase Angle for Output
On/Off function can set the starting angle and ending angle of the voltage output according to the test requirements. V-Limit, Ipeak-
Limit, F-Limit, OVP, OCP, OPP function settings can protect the DUT during the measurement process. In addition to OTP, OCP, and
OPP protection, the ASR-2000 series also incorporates the Fan fail alarm function and AC fail alarm function.
The front panel of the ASR-2050/2100 provides a universal socket or a European socket, which allows users to plug and use so as to save
wiring time. The ASR-2050R/2100R is 3U height and 1/2 Rack width design, which is compatible with ATS assembly. The ASR-2000 series
supports I/O interface and is equipped with USB, LAN, External I/O and optional RS-232C and GPIB.