Manual

APS-9301 & APS-9501 & APS-9102 User’s Manual
16
8. Specifications
This section contains a table of APS-9301/9501/9102 characteristics.
Table 1: Specification
Specification Description
Output
Frequency
(45.0~500Hz)
Digital setting via keys, Resolution: 0.1Hz
Accuracy: ±0.1Hz
Output Voltage
(AC0.0 ~
300.0V)
Digital setting via keys, Resolution: 0.1Vrms
Accuracy: ±0.1%rdg+1digit
Output Capacity
Low voltage range: 0.0 ~ 150Vac
High voltage range: 0.0 ~ 300Vac
Output Power 300VA(9301); 500VA(9501); 1KVA(9102)
Maximum
Current
APS-9301: 2.6A(0~150V), 1.3A(0~300V)
APS-9501: 4.2A(0~150V), 2.1A(0~300V)
APS-9102: 8.4A(0~150V), 4.2A(0~300V)
Line Voltage
Regulation
±0.1%
Load Regulation ±(0.5%+0.1V)
Protection Key Lock, OCP, Short Circuit Protect,OTP
Frequency
Stability
100PPM
Wave Distortion
0.5%THD.(Resistance Load)
APS-9301 & APS-9501 & APS-9102 User’s Manual
17
Wattage Meter
Measuring
Range 0.0~360W (2A) 320 ~ 3500W
Resolution 0.1W 1W
Accuracy±1.5% rdg+5digits
±1.5% rdg+1digits
Power Factor
Meter
Measuring Range0.000 ~ 1.000
Resolution0.001
Accuracy±2% rdg + 2 digits
Line Input
Requirement
115/230Vac±15 %, 47-63Hz, 1 phase
Calibration Front Panel Software Calibration
AC Power
consumption
Maximum 2.8KW
Operation
Environment
Indoors
Rated Temperature+10
0
C ~+35
0
C
Operating Temperature: +0
0
C ~+40
0
C
Storing Temperature-10
0
C ~+70
0
C
Relative Humidity:<80%
Accessory
Operation manual……………..x1
Line cord………………………x1
(APS-9301/9501)
APS-9301/9501137mm(H) x 430(W) x 500mm(D)
Dimensions
APS-9102225mm(H) x 430(W) x 500mm(D)
Weight Approximate 20/25/35kg (APS-9301/9501/9102)
Digital Display:
Frequency Counter
Measuring Range0.0~999Hz
Resolution0.1Hz
Accuracy±0.1Hz
RMS Voltmeter
Measuring RangeAC0.0 ~ 380V
Resolution0.1Vrms
Accuracy±1% rdg+1digit
RMS Ammeter
Measuring
Range 0.000~2.000A 1.80 ~ 35.00A
Resolution 1mA (360W) 0.01A
Accuracy±1% rdg+5digits ±1% rdg+2digit s