Connection to output terminals (rear)
Outputs are isolated from the input power lines and the case (ground connection). When connecting to
an output terminal, attach a round crimp contact with a sleeve that has sufficient capacity for the output
current.
DC output is based on “Lo”, so that the + polarity setting sets “Hi = positive”, and the - polarity
setting sets “Hi = negative”.
Output terminal
Figure 3-5. Output Terminals (Rear)
When output is on, do not touch the output terminal block.
To ensure safety, always attach the supplied terminal cover.
!