9 SPECIFICATIONS
APS-1102A
9-5
m) Small amplitude frequency response
(When signal source mode is INT, 100 V range, output voltage is 20 Vrms, 50 Hz rating)
AC mode 40 Hz to 550 Hz: 1%
AC+DC mode 40 Hz to 550 Hz: 1%
n) Output voltage distortion factor 0.5% or less
(50 Hz or 60 Hz, 50% or higher of the rated output voltage, the
maximum current or lower, THD+N)
o) Output voltage stability
Fluctuation with output current: 45 Hz to 65 Hz Within 0.15%
DC, 40 Hz to 550 Hz Within 0.5%
(In the case that the output current is changed from 0% to 100%
of the maximum current, at the output terminal, the rated output
voltage)
Fluctuation with input voltage: Within 0.2%
(The power supply input voltage is 100 V, 120 V or 230 V, no
load, the rated output voltage)
p) Output DC offset
100 V range: Within50 mV (typ., fine adjustment available)
200 V range: Within 100 mV (typ., fine adjustment available)
(AC - INT mode, output voltage setting = 0 V)