User Manual User guide
6 REMOTE INTERFACE
APS-1102A
6-19
[SOURce:]CURRent:LIMit:AVErage
This sets the upper limit for the output RMS current. The output RMS current limiter setting
ranges from 1.0 A to 10.5 A (for 100 V range) or from 1.0 A to 5.3 A (for 200 V range). To keep
compatible with APS-1102, current average limiter command of APS-1102 can be used as RMS
limiter command of APS-1102A.
Syntax: [SOURce:]CURRent:LIMit:AVErage<NR2>
Parameter: 1.0 to 10.5 (1.0 to 5.3)
Command example: CURR:LIM:AVE 5
Query example: CURR:LIM:AVE ?
Response format: <NR2>
Response example: 5.0
[SOURce:]CURRent:LIMit:PEAK:HIGH
This sets the upper limit of the output peak current (positive polarity). The output peak current
limiter (positive polarity) setting ranges from 10.0 A to 42.0 A (for 100 V range) or from 5.0 A to
21.0 A (for 200 V range).
Syntax: [SOURce:]CURRent:LIMit:PEAK:HIGH<NR2>
Parameters: 10.0 to 42.0 (5.0 to 21.0)
Command example: CURR:LIM:PEAK:HIGH 10
Query example: CURR:LIM:PEAK:HIGH?
Response format: <NR2>
Response example: 10.0
[SOURce:]CURRent:LIMit:PEAK:LOW
This sets the upper limit for output peak current (negative polarity). The output peak current
limiter (negative polarity) setting ranges from 42.0 A to 10.0 A (for 100 V range) or from 21.0
A to 5.0 A (for 200 V range).
Syntax: [SOURce:]CURRent:LIMit:PEAK:LOW<NR2>
Parameters: 42.0 to 10.0(21.0 to 5.0)
Command example: CURR:LIM:PEAK:LOW 10
Query example: CURR:LIM:PEAK:LOW?
Response format: <NR2>
Response example: 10.0