User Manual Manual
9.2 Current Limiter
APS-1102 Programmable AC/DC Power Source 9-6
9.2 Current Limiter
Output peak current limiter
When limiter is operating, output voltage is clipped.
Positive current setting range 100 V range: +10.0 A to +42.0 A
(Initial value: +42.0 A)
200 V range: +5.0 A to +21.0 A
(Initial value: +21.0 A)
Negative current setting range: 100 V range: 42.0 A to 10.0 A
(Initial value: 42.0A)
200 V range: 21.0 A to 5.0 A
(Initial value: 21.0 A)
Setting resolution: 0.1 A
Output average current limiter
When limiter is operating, suppresses output voltage.
Current setting range 100 V range: 1.0 A to 10.5 A (Initial value: 10.5 A)
200 V range: 1.0 A to 5.3 A (Initial value: 5.3 A)
Setting resolution: 0.1 A
9.3 Setting Range Limits
When signal source mode is internal or internal + external only
Voltage setting limit
(Lower limit upper limit)
Positive voltage setting range 100 V range: +5.0 V to +200.0 V (Initial value: +200.0 V)
200 V range: +10.0 V to +400.0 V (Initial value: +400.0 V)
Negative voltage setting range 100 V range: 200.0 V to 5.0 V (Initial value: 200.0 V)
200 V range: 400.0 V to 10.0 V (Initial value: 400.0 V)
Setting resolution: 0.1 V
Frequency setting limit
(Lower limit upper limit)
Upper limit setting range: 1.0 Hz to 550.0 Hz (Initial value: 550.0 Hz)
Lower limit setting range: 1.0 Hz to 550.0 Hz (Initial value: 1.0 Hz)
Setting resolution: 0.1 Hz