9.1 Output
APS-1102 Programmable AC/DC Power Source 9-2
Unless otherwise noted, the following conditions are adopted:
Power input: 200 V AC, 50 Hz
Output mode: AC-INT (alternate current - internal signal source) mode
Output frequency: 50 Hz
Output voltage: 100 Vrms (200 Vrms when in 200 V range)
Output waveform: Sine wave
Load 100 V range: 10 (power factor 1, nominal value)
200 V range: 40 (power factor 1, nominal value)
Output terminals: Terminal block on rear panel
9.1 Output
Output mode
All eight modes (combination of operation mode + signal source mode)
AC-INT mode (alternate current - internal signal source)
AC-EXT mode (alternate current - external signal source)
AC-ADD mode (alternate current - internal + external source)
AC-SYNC mode (alternate current - external synchronization)
AC+DC-INT mode (direct current - internal signal source)
AC+DC-EXT mode (direct current - external signal source)
AC+DC-ADD mode (direct current - internal + external source)
AC+DC-SYNC mode (direct current - external synchronization)
Output voltage ranges
100 V range and 200 V range
Maximum output power
750 VA (AC) / 750 W (DC)
Power supply input conditions: 100 V AC to 180 V AC input
(hereinafter referred to as “AC 100 V input system”)
Output voltage conditions: 130 Vrms (AC) / 183 V (DC) or lower (100 V range)
260 Vrms (AC) / 366 V (DC) or lower (200 V range)
1000 VA (AC) / 1000 W (DC)
Power supply input conditions: 180 V AC to 250 V AC input
(hereinafter referred to as “AC 200 V input system”)
Output voltage conditions: 135 Vrms (AC) / 190 V (DC) or lower (100 V range)
270 Vrms (AC) / 380 V (DC) or lower (200 V range)