User Manual Manual

6.3 Command Descriptions
APS-1102 Programmable AC/DC Power Source 6-41
TST?
This returns the self test results. In this device, “0” is always returned.
Syntax: TST?
Parameters: None
Query example: TST?
Response format: <NR1>
Response example: 0
WAI
When all operations
are completed, the device is not able to execute any subsequent commands.
This is to prohibit the device from executing any subsequent command until all the operations are
completed.
Syntax: WAI
Parameters: None
Command example: WAI
Response format: None
Response example: None
“Operations” means execution process of any commands in the following.
Output mode setting [SOURce:]MODE
Output range setting [SOURce:]VOLTage:RANGe
Output relay control OUTPut[:STATe]
Sequence execution PROGram[:SELected]:EXECute
Memory recall RCL
Device reset RST