6.3 Command Descriptions
APS-1102 Programmable AC/DC Power Source 6-32
STATus:WARNing:ENABle
This sets the warning event enable register. The setting ranges from 0 to 31999.
Syntax: STATus:WARNing:ENABle <NR1>
Parameters: 0 to 31999
Command example: STAT:WARN:ENAB 1
Query example: STAT:WARN:ENAB?
Response format: <NR1>
Response example: 1
STATus:WARNing[:EVENt]?
This returns the warning event register value. The response ranges from 0 to 31999.
Syntax: STATus:WARNing[:EVENt]?
Parameters: None
Query example: STAT:WARN?
Response format: <NR1>
Response example: 0
STATus:WARNing:NTRansition
STATus:WARNing:PTRansition
This sets the warning transition filter (WRTF). The setting ranges from 0 to 31999.
When the NTR filter is set to 1, WRER is set to 1 when WRCR changes from 1 to 0.
When the PTR filter is set to 1, WRER is set to 1 when WRCR changes from 0 to 1.
When the NTR and PTR filters are set to 1, WRER is set to 1 when WRCR changes.
When the NTR and PTR filters are set to 0, changes in WRCR are not propagated to WRER.
Syntax: STATus:WARNing:NTRansition <NR1>
STATus:WARNing:PTRansition <NR1>
Parameters: 0 to 31999
Command example: STAT:WARN:NTR 16384
STAT:WARN:PTR 0
Query example: STAT:WARN:NTR?
STAT:WARN:PTR?
Response format: <NR1>
Response example: 16384
0