User Manual Manual

6.3 Command Descriptions
APS-1102 Programmable AC/DC Power Source 6-16
[SOURce:]FREQuency:LIMit:HIGH
This sets the upper limit of the frequency that can be set. However, a value that is at or below the
currently set frequency cannot be set. ([5, “Out of Limiter”] error occurs.)
The limit value setting ranges from 1.0 to 550.0 Hz.
Syntax: [SOURce:]FREQuency:LIMit:HIGH <NR2>
Parameters: 1.0 to 550.0
Command example: FREQ:LIM:HIGH 550
Query example: FREQ:LIM:HIGH?
Response format: <NR2>
Response example: 550.0
[SOURce:]FREQuency:LIMit:LOW
This sets the lower limit of the frequency that can be set. However, a value that is at or above the
currently set frequency cannot be set. ([5, “Out of Limiter”] error occurs.)
The limit value setting ranges from 1.0 to 550.0 Hz.
Syntax: [SOURce:]FREQuency:LIMit:LOW <NR2>
Parameters: 1.0 to 550.0
Command example: FREQ:LIM:LOW 50
Query example: FREQ:LIM:LOW?
Response format: <NR2>
Response example: 50.0
[SOURce:]FUNCtion[:SHAPe][:IMMediate]
This sets the output waveform. The output waveform setting is SIN/SQU/ARB1 to ARB16.
When in AC-EXT/AC+DC-EXT mode, the output waveform cannot be set. ([3, “Invalid in this
mode”] error occurs.)
Syntax: [SOURce:]FUNCtion[:SHAPe][:IMMediate] <CRD>
Parameters: SIN/SQU/ARB1 to ARB16
Command example: FUNC SIN
Query example: FUNC?
Response format: <CRD>
Response example: SIN