User Manual Manual
5.3 SET Menu
APS-1102 Programmable AC/DC Power Source 5-21
5.3.8 Output average current limiter settings
This limits the output average current.
When the output average current exceeds this setting, the output voltage is suppressed.
Table 5-17. Output Average Current Limiter Setting Range
Setting Setting Range Resolution Initial Value
Output average
current limiter
100 V range 1.0 A to 10.5 A 0.1 A 10.5 A
200 V range 1.0 A to 5.3 A 0.1 A 5.3 A
Operation steps
Select
in the SET menu and set numerical values.
See “3.4.7 Using limiter functions”, for description of the output average value current
limiter.