User manual
REMOTE INTERFACE
269
SOURce[1]:ARB:BUILt:RAMP
Source Specific
Command
Description
Creates a ramp wave with a specified start
address, length and scale.
Syntax SOURce[1]:ARB:BUILt:RAMP[<STARt>[,<LENGth>[,<S
CALe>]]]
Parameter <STARt> Start address*: 0~1048,576
<LENGth> Length*: 0 ~ 1048,576
<SCALe> Scale: ±32767
* Start + Length ≤ 1,048,576
Example SOUR1:ARB:BUIL:RAMP 1000, 1000, 100
Creates a ramp wave 1000 points in length with a
scale of 100 and a start address of 1000.
SOURce[1]:ARB:BUILt:SINC
Source Specific
Command
Description
Creates a sinc wave with a specified start address,
length and scale.
Syntax SOURce[1]:ARB:BUILt:SINC
[<STARt>[,<LENGth>[,<SCALe>]]]
Parameter <STARt> Start address*: 0~1048,576
<LENGth> Length*: 0 ~ 1048,576
<SCALe> Scale: ±32767
* Start + Length ≤ 1,048,576
Example SOUR1:ARB:BUIL:SINC 1000, 1000, 100
Creates a sinc wave 1000 points in length with a
scale of 100 and a start address of 1000.