Sweep Time
The sweep time is used to determine how long it takes to perform a
sweep from the start to stop frequencies. The function generator
automatically determines the number of discrete frequencies used in
the scan depending on the length of the scan.
Panel Operation
1. Press the SWEEP key.
2. Press F5 (SWP Time).
3. The Sweep Time parameter will become
highlighted in the Waveform display area.
4. Use the selector keys and
scroll wheel or number pad
to enter the Sweep time.
5. Press F1~F2 to select the
time unit.
~
Range Sweep time 1ms ~ 500s