User manual

AFG-200 SERIES USER MANUAL
Couple
The Couple commands can be used to remotely set the frequency
coupling and amplitude coupling.
SOURce[1|2]:FREQuency:COUPle:MODE
Instrument
Command
Description
Set the frequency coupling mode.
Syntax SOURce[1|2]:FREQuency:COUPle:MODE
{Off|Offset|Ratio}
Example SOURce1:FREQuency:COUPle:MODE Offset
Sets the frequency coupling mode to offset.
Query Syntax
SOURce[1|2]:FREQuency:COUPle:MODE
Off Disables frequency coupling. Return Parameter
Offset Set frequency coupling to offset mode.
Ratio Sets frequency coupling to ratio mode.
Example
SOURce1:FREQuency:COUPle:MODE
Off
Frequency coupling is turned off.
SOURce[1|2]:FREQuency:COUPle:OFFSet
Instrument
Command
Description
Sets the offset frequency when the frequency
coupling mode is set to offset.
Syntax SOURce[1|2]:FREQuency:COUPle:OFFSet {frequency}
Example SOURce1:FREQuency:COUPle:OFFSet 2khz
Sets the offset frequency to 2kHz (the frequency of
CH2 minus CH1 is 2kHz).
Syntax SOURce[1|2]:FREQuency:COUPle:OFFSet?
Example SOURce1:FREQuency:COUPle:OFFSet?
+2.0000E+03
96