User manual
AFG-200 SERIES USER MANUAL
5. Choose the sweep time using the
SOURce[1|2]:SWE:TIME command.
6. Select an internal or external sweep trigger
source using the SOURce[1|2]:SOUR
command.
Select Sweep
Time
Select the sweep
trigger source
Select the marker
frequency
7. To output a marker frequency from the
trigger out, use The
SOURce[1|2]:MARK:FREQ command. To
enable marker frequency output, use the
SOURce[1|2]:MARK ON command.
The marker frequency can be set to a value within
the sweep span.
SOURce[1|2]:SWEep:STATe
Source Specific
Command
Description
Sets or disables Sweep mode. By default Sweep is
disabled. Sweep modulation must be enabled
before setting other parameters.
Note
Any modulation modes or Burst mode will be
disabled if sweep mode is enabled.
Syntax SOURce[1|2]:SWEep:STATe {OFF|ON}
Example SOUR1:SWE:STAT ON
Enables sweep mode.
Query Syntax SOURce[1|2]:SWEep:STATe?
Return Parameter
0 Disabled (OFF)
1 Enabled (ON)
Example SOUR1:SWE:STAT?
1
Sweep mode is currently enabled.
71