User manual
REMOTE INTERFACE
129
Return Parameter
0
Counter function is off.
1
Counter function is on.
Query Example
COUN:STAT?
>1
Counter is on.
COUNter:VALue?
Query
Description
Queries the counter frequency.
Note
The counter function is only applicable for the
AFG-21XX models.
Syntax
COUNter:VALue?
Return Parameter
<NR3>
Returns the counter frequency.
Example
COUN:VAL?
>1.000E+03