SOURce[1]:SWEep:SPACing
Set
Query
Sets linear or logarithmic sweep spacing. The
default spacing is linear.
SOURce[1]:SWEep:SPACing {LINear|LOGarithmic}
SOUR1:SWE:SPAC LIN
Sets the spacing to linear.
SOURce[1]:SWEep:SPACing?
LIN
Linear spacing
LOG
Logarithmic spacing
SOUR1:SWE:SPAC?
>LIN
The spacing is currently set as linear.
SOURce[1]:SWEep:RATE
Set
Query
Sets or queries the sweep rate. The default sweep
rate is 100 Hz. This command is the equivalent to
using the Rate function on the front panel.
The function generator automatically determines
the number of frequency points that are used for
the sweep based on the sweep rate.
SOURce[1]:SWEep:RATE
{<Hz>|MINimum|MAXimum}
<Hz>
2mHz ~1kHz (equivalent to a sweep
time of 500s ~ 1ms)
SOUR1:SWE:RATE +1.0000E+00
Sets the rate to 1 Hz (1 second).
SOURce[1]:SWEep:RATE? {<Hz>|
MINimum|MAXimum}
<NR3>
Returns sweep rate in Hz.