Datasheet

AC LOAD MODE
5
Simply Reliable Good Will Instrument Co., Ltd.
AC & DC Electronic Load
CC Mode : In the constant current mode of AC Load, can be applied to sine wave voltage source, providing CF,
PF test of linear load.
Linear Constant Current Mode : Can be applied to sine wave and non-sine wave voltage source, as shown in the PWM
inverter driver, step voltage source, and off-line UPS sine wave switch to square wave, square wave switch to sine wave.
Supported on-load start-up : at first set Load ON to support on-load start-up, inverter or uninterruptible power supply
is start-up directly with the set load current, used to verify whether the Inverter is stable when the load is connected
during start-up.
I
V
CC mode
I
V
Linear CC mode
CC 10 A on-load boot CR 10 A on-load boot
CV 10 A on-load boot
CC mode, CF = 2 CC mode, CF = 5 CC mode, CF = +0.5 CC mode, CF = -0.5
Linear CC mode, PWM 10A 2.5Hz to 250Hz
Linear CC mode, PWM 10A 2.5Hz Linear CC mode, PWM 10A 250Hz
Linear CC mode, Step 10A
Linear CC mode, UPS Sine to
Square Waveform
Linear CC mode, UPS Sine to
Square Waveform