Datasheet
Table Of Contents
AEL-5000 S
eries AC & DC electronic load has built-in new TYPE1 ~ TYPE3 battery discharge test, you can
select the desired battery test mode, the test results can be directly displayed on the LCD display for
battery AH capacity, the voltage value after discharge and the cumulative discharge time.
The
AEL-5000 S
eries AC & DC load provides multiple units in parallel, three-phase applications that allows
users to test applications with greater power or three-phase AC power, this is more flexibility to use the
AEL-
5000
Series AC & DC Electronic Load for control. In parallel / three-phase operation, the user operates
the unit as the operation of a single machine, as long as the Master can be operated, Slave1 and Slave2
will automatically sink the load and measurement. Parallel and three-phase connection as shown below.
BATTERY TEST FUNCTION
CP + UVP Battery discharge mode
Type 2
Programmed battery discharge time
Type 3
CC + UVP Battery discharge mode
Type 1
Battery Current Battery Current Battery Current
Constant Current Constant CurrentConstant Power
PARALLEL AND THREE-PHASE CONTROL
Maximum power of single-phase can up to 180KW, 3-phase total power up to 540KW 3-phase △ or Y Connection
L 1
N
GPIB, RS-232, USB,
LAN or Manual
Master Slave 1
L2
N
Master Slave 1
Ø1
L3
N
Master Slave 1
Ø2
Ø3
L 2
L 3
N
Support 1 master and up to 7 slaves operation.
Maximum up to 8 units can be connected in parallel,
total power of single-phase can up to 180 kW
Support 1 master and up to 7 slaves operation.
Maximum up to 8 units can be connected in parallel,
total power of single-phase can up to 180 kW
Support 1 master and up to 7 slaves operation.
Maximum up to 8 units can be connected in parallel,
total power of single-phase can up to 180 kW
GPIB, RS-232, USB,
LAN or Manual
GPIB, RS-232, USB,
LAN or Manual
GPIB, RS-232, USB,
LAN or Manual
GPIB, RS-232, USB or LAN Interface
Slave 1 Slave2 Master Slave 1 Slave2 Master
11
Simply Reliable Good Will Instrument Co., Ltd.
AC & DC Electronic Load