Datasheet

Set a complete sequence editing function to
obtain following waveforms. Users can save
development cost and time without using a
PC to control electronic load and writing
programs.
Fast Sequence Diagram
Power-driven Tools Simulation Test
Normal Sequence Diagram
FAST SEQUENCE & NORMAL SEQUENCE
C.
Measurement Load Current
Fulfilling Production Test
Simulating Load Current
The Soft Start function of PEL-3000E Series allows users to
determine the rise time of current sink that is to decide how
much time is required to reach electronic load's set current,
resistance or power value. PEL-3000E's soft start function
prevents inrush current and surge voltage from happening
on DUT.
SOFT START
D.
For instance, test applications using a power supply, LED and
a DC load (activate the soft start function) can prevent inrush
current and surge voltage from causing damages on LED.
When operating the Sequence Function, PEL-3000E Series
follows the time and load settings of step1, step2,
so as to realize different load current variation.
step3, etc.
Ramp function of PEL-3000E Series is able to set the current
transition. When turned on, the current takes on a slope form;
when turned off, the current takes on a step form.