- Menu Tree / Operation Shortcuts
- Convention
 - Acquire Key
 - Acquire Key - Segments
 - Autoset Key
 - CH1 ~ 4 Key
 - Cursor Key
 - Display Key
 - Help Key
 - Math Key
 - Measure Key
 - Hardcopy Key
 - Run/Stop Key
 - REF Key
 - Save/Recall Key
 - Test Key
 - Test Key – Go-NoGo
 - Trigger Type Menu
 - Trigger Edge Menu
 - Trigger Delay Menu
 - Trigger Pulse Width Menu
 - Trigger Video Menu
 - Trigger Pulse Runt Menu
 - Trigger Rise & Fall Menu
 - Trigger Timeout Menu
 - Utility Key
 - Utility Key – I/O
 - Utility Key – File Utilities
 - Utility Key – Wave Generator - Demo Outputs
 - Search - Edge
 - Search – Pulse Width
 - Search - Runt
 - Search – Rise/Fall Time
 - Zoom Key
 - Option Key
 
 - Default Settings
 - Built-in Help
 
 - Menu Tree / Operation Shortcuts
 - MEASUREMENT
 - CONFIGURATION
 - OPTIONAL SOFTWARE and APPS.
 - SAVE/RECALL
 - FILE UTILITIES
 - HARDCOPY KEY
 - REMOTE CONTROL CONFIG
 - MAINTENANCE
 - FAQ
- I connected the signal but it does not appear on the display.
 - I want to remove the (Measurement result / FFT result / Help contents) from the display.
 - The waveform does not update (frozen).
 - The probe waveform is distorted.
 - Autoset does not catch the signal well.
 - I can’t save files to the internal memory.
 - The display image printout is too dark on the background.
 - The date and time settings are not correct.
 - The accuracy does not match the specification.
 
 - APPENDIX
 - INDEX
 
    CONFIGURATION 
149 
Event 
Sets the number of events (1 ~ 65535) 
passed after the trigger event, until the 
real trigger timing. 
Set to 
Minimum 
Sets the source trigger to the minimum 
time. 
When 
(Pulse Width) 
Sets the pulse width (10ns ~ 10s) and the triggering 
condition. 
> 
Longer than 
= 
Equal to 
< 
Shorter than 
≠ 
Not equal to 
Threshold 
(Pulse Width) 
Sets the amplitude threshold level for the pulse 
widths. 
Threshold 
–XXV ~ +XXV, user-set level 
Set to TTL 
1.4V 
Set to ECL 
-1.3V 
Set to 50% 
Sets the threshold to 50% 
Standard 
(Video) 
NTSC 
National Television System 
Committee 
PAL 
Phase Alternate by Line 
SECAM 
SEquential Couleur A Memoire 
Polarity 
(Pulse Width, 
Video) 
Positive polarity (triggered on the high 
to low transition) 
Negative polarity (triggered on the 
low to high transition) 
Polarity 
(Pulse Runt) 
Positive polarity (positive runt) 
Negative polarity (negative runt) 
Either (either negative or positive 
runt) 
Trigger On 
 Selects the trigger point in the video signal. 