User's Manual

57
13.3.1 Synchronize
This button can be used to initiate the synchronizing process only for the selected logger instead of
synchronizing all loggers. "Synchronizing" is the process of sending logger setup data and receiving
measurement data, for details see Logger Synchronization. After synchronizing the logger can't be re
synchronized for about 1 min. (durin
g synchronization of all loggers: 5 min.). The button is enabled after
successfulconnectiontologger.
13.3.2 Remote listening
Remote listening is initiated/terminated by pressing the Remote listening button (enabled after successful
connectiontologger).ThenoisesignalmonitoredbytheloggerwillbesenttothePC'ssoundoutputdevice
depending on the hardware configuration (e.g. internal or external speakers, headphone, lineout, etc.).
There'sa slight dela
ybetween the real noisesignal and the output signal. After 8seconds remotelistening
willbeinterruptedforabouthalfasecond.Thispauseisnecessaryforresyncronizingtheradiotransmission.
Volume:DisplaysaWindows™builtinutilitysoftwarethatallowsadjustmentofthevolume.
Notes:
Remotelisteni
nginvolvesconsiderablecurrentconsumption,thusdecreasingthelogger'sbatterylifetime.It
shouldn'tbeinitiatedtoooftenwithoutnecessityinordertopreservebatterypower.
Remotelisteningshouldn'tbeinitiatedduringmeasurement,i.e.duringtheprogrammedmeasurementtime
ofthelogger(seeLoggerSetup),asitmightaffectcollectingoftheanal
ysisdata.
13.4 LoggerSetup(WizardAssistedVersion)
TheLoggerSetupwindowmaybedisplayedbyselectingtheappropriatemenuitemorbysimplypressingF4.
Itallowsadjustmentofthepropertiesoftheactualselectedlogger:
Loggerno.:Eachloggerhasitsownuniqueloggernumberthatisneede
dforidentification.Thisnumbercan
befoundontheloggercase.ThenumberhastobeenteredexactlyintotheLoggerno.fieldforeachlogger
oftheproject,otherwisetheloggercannotbefoundbytheCommLink.
Position:Ashortdescriptionofthepositiontheloggerisdeploye
d.Somedatashouldbeenteredbymeans
ofeasieridentificationofthelogger.
Thenavigation buttonsmaybeused to switchtoanotherlogger withoutleaving theLogger Setupwindow.
Anychangestothesettingswon't besavedtotheinternal databaseunlesstheyareconfirmedorcancelled
by th
e user. Confirmation is done by pressing the ok symbol button or the Return key or by switching to
anotherlogger,cancellationisdonebypressingtheXsymbolbuttonortheEscapekey.
In case the Logger Setup window is invoked by the Insert logger function, there's also an I
nsert multiple
loggersbutton.Thisfunctionallowseasyinsertionofasequenceofloggerswithconsecutiveloggernumbers.
Afterpressingthisbuttonandenteringthenumbersofthefirstandthelastlogger,pressingOKwillinsertall
loggersatonce.