Safety Guidelines & Installation Manual Language: English Version: 1.
Table of Contents 1 Indications for Use.......................................................................................................... 3 1.1 Symbols .................................................................................................................. 3 1.2 Safety ...................................................................................................................... 4 1.3 Intended Use ................................................................................
1 Indications for Use It is essential to read the operating instructions carefully and completely before using the first time the equipment and software. They contain important information on safety, installation and use. Keep these instructions in a safe place. 1.1 Symbols Warning of dangerous situations that can cause injury and damage to the devices. Warning of non-ionising electromagnetic radiation. Important notes and tips are a sign Info provided. Follow these guidelines.
1.2 Safety The operating and maintenance personnel must read the instructions carefully before using the equipment. Knowing all the information contained therein - in particular the warning and safety instructions - is needed to safely operate the equipment, and to protect yourself and others against possible dangers. Ignoring the warning, safety and operating instructions can result in injury, damage, or a considerable shortening of the equipment life time.
2 Delivery Contents The ALPHA System contains the following components: ALPHA V2: Communication between loggers and repeaters Solar panel: Recharges the battery of the ALPHA Power cord: For the connection between the ALPHA and the solar panel Fastening material: For fastening the ALPHA and the solar panel External antenna (optional): For enhanced data transmission 5 I 19
3 Mechanical Installation ZONESCAN ALPHA is the data gateway for HISCAN and ZONESCAN 820 permanent monitoring systems. Especially when in use in conjunction with ZONESCAN 820 system, which is spread out over a larger area, it is recommended to place the ALPHA at the highest position available in order to ensure the best radio connection possible. 3.1 Safety Precautions You must ensure that there is adequate safety present when working at great heights.
3.2.1 SIM Card Open the ALPHA carefully. The SIM card slot is located at the top of the device. Place the SIM card as shown and insert it into the slot: Before closing the ALPHA, check the seal. Remove any dirt and exchange it if damaged. Close the lid and fasten the screws tightly.
3.2.2 Tool setting via pushbutton and LED indication The device is equipped with a push button and one LED that can indicate red and green. This allows to enforce some fundamental settings. • Switch the device into the sleep mode and wake it up from the sleep mode: In the sleep mode nearly all functions of the device are disabled and the power consumption is reduced to the minimum. This mode is designated for longer periods of non-usage. The only available function is to be prepared for a wake-up.
3.2.3 Mounting the ALPHA On the back side of the ALPHA there is a metal mounting plate which enables secure installation also to round objects. Make sure to use mounting material suitable for the environment. To ensure redundancy, it is mandatory to use always two fastening elements for the ALPHA housing. Do not use the ALPHA if it is damaged. Mount the ALPHA with its connectors oriented towards the bottom.
Modem antenna location Internal on both sides Modem antenna provision Free line of sight to the base station is optimal Internal radio antenna location Internal antenna below the lid Internal radio antenna provision Free line of sight to the repeater is optimal 10 I 19
3.3 Directions for the Power Supply The main power supply for the ALPHA is a solar panel which is used to charge the internal battery. If an alternative power supply (12VDC ±10% / 4W) is used, it must be installed by a skilled electrician in compliance with local regulations. At the back side of the solar panel there is a metal mounting plate similar to that of the ALPHA. Make sure to use mounting material suitable for the environment.
3.4 Directions for External Antennas 3.4.1 Directional Antenna YA9-11 This Yagi type antenna is a directional antenna with a main horizontal distribution at +/- 30 ° of the direction it is pointed to. It is best used, if the ALPHA is placed outside the installation area of loggers that should be covered. Mounting clamp fits poles up to 50 mm. Always use both clamps and securely tighten the screws. The little staves should be oriented vertically for correct polarisation.
3.4.2 Omnidirectional Antenna XL-900-3LW This 70 cm rod antenna is an omnidirectional antenna. It is best used, if the ALPHA is placed within the installation area of loggers which should be covered. Mounting clamp fits poles up to 50 mm. Always use both clamps and securely tighten the screws. The rod should be oriented vertically for correct polarisation.
4 Technical Data 4.1 Mechanical Dimensions Parameter Comment min. typ. max. Unit 152 mm 102 mm 95 mm 1.
4.2 Used Radio Frequencies System Frequency Gutermann Radio (internal) 869.525 MHz Gutermann Radio (external) 869.
4.3 Battery Type LiFePO4 Number of cells 4 Voltage 3.3 V / 3.6 V (nominal / charge) Capacity 33 Wh / 10 Ah Charging temperature -30 °C – 55 °C 4.4 Pin Assignment 4.4.1 Power Connector M8 Connector 3 Pin Signal 1 +12VDC / 4W Input 3 NC 4 Ground 1 4 4.4.2 Antenna Connector 1 to 3 Connector: RP-TNC Connector RP-TNC; Plug (IP67 connected) Pin Signal 1 Signal case Ground 1 case 4.
Antenna gain: 11dBi max. Polarisation: linear; vertical Minimum safe distance: 0.2 m 5 Storage and Transport In order to avoid unwanted radio transmissions and prevent battery depletion, the ALPHA must be set to sleep mode for storage and transportation. In sleep mode, the ALPHA will listen on the Gutermann radio every 30 seconds, but not transmit. The modem will also stay switched off. In order to enter sleep mode, open the ALPHA, press the button at the top and keep it pressed for 2 seconds.
8 Conformity This device contains licence-exempt transmitter(s)/receiver(s) that comply with Innovation, Science and Economic Development Canada’s licence-exempt RSS(s). Operation is subject to the following two conditions: 1. This device may not cause interference. 2. This device must accept any interference, including interference that may cause undesired operation of the device.
9 Important Information Please draw your attention to all warnings and information in the manual and on the products. By using this product, you acknowledge that you are aware of and have read the warnings and information provided in the manual. Always clean the sensors and mechanical accessories with a clean towel after use before stowing them away in the carry case.