User's Manual

20 I 72
This is the total Pipe Length between Logger 1 and Logger 2
Located in the Pipe Setup field are red, yellow or green indicators
Red indicators indicate that no pipe settings have been entered yet
and the used data were taken over from the default values
Yellow images appear if manual settings were made and not all
details are known (pipe length, diameter and material are known).
With manual settings, the course of the pipe cannot be changed,
unlike with the Pipe Wizard
Green indicators mean that all details are known for the settings
and were taken over in full from the Pipe Wizard
To enter the pipe settings, use the mouse to click the small
triangles, next to Comments, in the field that you would like to
change. In the menu that appears, select “Manual Pipe Data Entry”
if you would like to enter the data "manually" or “Start Pipe Wizard”
if the data are to be determined automatically. To delete existing
pipe data, select the “Delete Pipe Information” item
Figure 19: Entering pipe settings
3.2.2 Entering Pipe Data Manually
Pipe Length
Pipe Set
up