User's Manual
68
AmplitudeDistributionHistogramResult
Expanded
Step1–establishthe“no‐leak”noise
levelinthearea.Minimumnoiseis4db
Step2–identifyareas2or3dbhigher
thanthe“no‐leak”level.Minimumnoiseis
7db
Step3–Determinethe
AreasofInterest.Analyseth
e
minimumnoiselevelforeachloggedpoint.
Higherminimumnoiselevelsareclosertotheleak
Usethese3stepstohelpdeterminewhich
logger(s)theleaksisnearto,thisisespecially
usefulinquietPVCenvironments.