User's Manual

56
13.3 LoggerState(WizardAssistedVersion)
TheLoggerStatewindowmaybedisplayedbyselectingtheappropriatemenuitemorfunctionbuttoninthe
main window or by simply pressing F3. It allows checking of the logger's settings, battery state and
availabilityofmeasurements.Additionally,there'saremotelisteningfunctionthatallowstheuserto"listen"
tothelogger'sinputsignal.
After ope
ning the window the software first tries to establish a connection to the Comm Link. Then the
CommLinktriestoobtainloggerstateinformationoftheselectedloggerviaradiotransmission.Thisprocess
maylastseveralseconds.Su
ccessisindicatedinthedisplayfieldnexttotheloggerno.field:
Loggerfound‐attempthasbeensuccessful
Loggerunreachable‐radiotransmissionhasfailed:eitherloggerisoutofradiotransmissionrange(thisisthe
commonreason)orloggerisoutofoperation
Errorin connection‐connectiontoCommLink ca
n'tbeestablished. possiblereasons:cable isnot properly
connectedtoPCorCommLink,wrongCOMportselected(seeProgramSetup)orbatteryvoltageofComm
Linkistoolow
Displayedinformation:
Loggerno.:Selectedlogger.Selectionmaybedonebyclickingonalistentryinthemainwindow'sloggerlist
or by using the navigation button on the to
p of the Logger State window. Logger state information can be
onlyobtainediftheloggerwithexactlythesamenumberonitscaseisinradiotransmissionrange.
Clock: Logger clock date and time. Logger clock will be up
dated during synchronization as soon as the
difference to the PC's clock exceeds 1 min. Thus, it is very important that the PC clock's time is checked
regularlyandwillbeadjustedifnecessary.
No.ofamplitudedistr.:Numberofavailableamplitudedistributions(1perday,max.10)
No.ofle
akvalues:Numberofavailableleakvaluemeasurements(1perday,max.180)
Soundsignalavail.:Indicateswhethersoundsignalrecordingisavailableornot
Next sound recording: Time of next sound signal recording. Sound signal recordings may be programmed
duringLoggerSynchronization.
Battery voltage: Battery voltage of the logger. Note: The voltage value of a fully lo
aded logger battery
typicallyremainsat3.0Vsteadilyforalongtime,asthevaluecan'texceed3Vduetointernalrestrictions.
Temperature:Temperatureinsidethelogger'scase
Startmeasurement:Programmedstartingtimeofdailymeasurement(seeLoggerSe
tup)
Stopmeasurement:Programmedstoptimeofdailymeasurement
Interval:Programmedmeasurementinterval
Versionno.:Loggerfirmwareversionno.
Radiooperationfrom:Startofradiooperationperiod(seeLoggerSetup)
Radiooperationto:Endofradiooperationperiod