SDS
US. OSHA Table Z-1 Limits for Air Contaminants (29 CFR 1910.1000)
ValueComponents Type
PEL 2400 mg/m3Acetone (CAS 67-64-1)
1000 ppm
PEL 9000 mg/m3
Value
Carbon Dioxide (CAS
124-38-9)
US. ACGIH Threshold Limit Values
Components Type
STEL 500 ppmAcetone (CAS 67-64-1)
TWA 250 ppm
STEL 30000 ppmCarbon Dioxide (CAS
124-38-9)
US. NIOSH: Pocket Guide to Chemical Hazards
ValueComponents Type
TWA 590 mg/m3Acetone (CAS 67-64-1)
250 ppm
STEL 54000 mg/m3Carbon Dioxide (CAS
124-38-9)
30000 ppm
TWA 9000 mg/m3
5000 ppm
Biological limit values
ACGIH Biological Exposure Indices
ValueComponents Determinant Specimen Sampling Time
25 mg/l Acetone Urine
*
Acetone (CAS 67-64-1)
* - For sampling details, please see the source document.
Good general ventilation (typically 10 air changes per hour) should be used. Ventilation rates
should be matched to conditions. If applicable, use process enclosures, local exhaust ventilation,
or other engineering controls to maintain airborne levels below recommended exposure limits. If
exposure limits have not been established, maintain airborne levels to an acceptable level. Provide
eyewash station.
Appropriate engineering
controls
Individual protection measures, such as personal protective equipment
Chemical respirator with organic vapor cartridge and full facepiece.
Eye/face protection
Skin protection
Wear appropriate chemical resistant gloves. Nitrile, butyl rubber or neoprene gloves are
recommended.
Hand protection
Wear appropriate chemical resistant clothing.
Other
Chemical respirator with organic vapor cartridge and full facepiece. Chemical respirator with
organic vapor cartridge and full facepiece if threshold limits are exceeded.
Respiratory protection
Wear appropriate thermal protective clothing, when necessary.
Thermal hazards
4 / 10
SDS
US
Material name: Gunk Brake Parts Cleaner - Non Chlorinated
M710 Version #: 01 Revision date: 02-21-2023 Issue date: 02-21-2023