Users Manual Part 1
Add/delete Analysis Objects
2. Press and hold any analysis object on the touch screen, and the
system will automatically pop up the object menu with the following
functions:
Control the display temperature marks: highest temperature, lowest
temperature and average temperature.
Emissivity: control the emissivity in the area.
Center: controls whether the analysis object is displayed in the center
Delete button: you may delete the current analysis object by touching
the [
] in the editing interface.
1. Click the shortcut menu [
] on the right of the real-time interface
to enter the menu interface of adding analysis objects, as shown in
the figure.
Providing temperature measurement for various analysis objects, such
as point, line, circle and rectangle. You can also customize the display
of the highest temperature, lowest temperature, average temperature
value and center display function, as shown in the figure.
Real-time Analysis