Cable Installation
The Radascan system is supplied without cables that are necessary to connect the sensor to the
DP system or to the PC control console. These must be supplied and fitted as required for a
particular vessel installation by the installer. The installer must provide power to the Radascan
sensor.
Cable Specification
Signal wiring to the DP and Control Console should be constructed of standard armored and
shielded data cable with a minimum of 5 cores and suitable for external marine applications
including UV and chemical resistance.
The power cable should be of external marine standard 3 core armored construction rated to 6
amps.
For Ethernet connection cable to the User console (and optional Ethernet link to the DP system),
Guidance Navigation recommend LEONI LI9Y(ST)C11Y 4x2x0.15 GN, whilst for connectors:
PHOENIX CONTACT Variosub RJ45 Quickcon CAT5e.
Connecting the power cables
Remove the hatch by unscrewing the M4 x 16mm socket screws and remove one of the screw
heads from the three cable glands and feed the cable through the water-proof gland.
You will need to strip 10 mm from the each of the three cores and connect each of the core into
the respective connection as specified below:
Radascan Installer – 7