User's Manual
Table Of Contents
Artemis Sensor Serial No.
Control PC Serial No.
Shipping Line
Vessel Name
Installer
Mechanical
Check Requirement Checked
(Initial)
Notes ⁄ Settings
Sensor Line of sight to expected remote stations.
Required space around and below the sensor.
All external connections secure and waterproofed.
The sensor is not in close proximity to other sources of high power X-band and S-band radar.
Interface box correctly sealed and tightened (if tted).
Sensor correctly secured to mounting.
Control PC Correctly located and fastened.
Cables correctly installed and fastened.
Correctly installed, routed to avoid power cabling.
Cables Cables fastened correctly.
Cables have service loops.
Installation Checklist
Electrical
Check Requirement Checked
(Initial)
Notes ⁄ Settings
Sensor Supplied by UPS (220-240 VAC, 50-60 Hz).
Cabling to control PC correctly wired.
Control PC Supplied by UPS (100-240 VAC, 50-60 Hz for Type 3 Marine Processor;
105-125 VAC or 220-240 VAC, 50-60 Hz for Hatteland Panel PC).
Sensor connection correctly wired.
DP connection correctly wired.
Cables Serial - capable of 38400 baud.
Ethernet – capable of 10Mbit/sec.
System System powers up and powers down correctly.
51