User's Manual

Installing a Beacon (Continued)
Setting Beacon Parameters with the Operating Panel
The setting of the following station parameters is described:
Station type
Frequency pair
Selective address code
Auto recovery
Configuration protection
IP address
The quickest way to set these parameters is by going through the configuration procedure.
1. Switch on the 230 VAC power to the antenna unit.
Note: The ON/OFF switch of the operating panel is not functioning!
2. Wait about 60 seconds for the station to start up.
3. Press Menu; the MAIN MENU MOB, MAIN MENU FIX or MAIN MENU BCN appears.
4. Press 5 (CONFIG). The following page appears:
If the second line reads MOB or FIX:
5. Press Enter; the cursor (<) starts blinking.
6. Press the or key until it reads BCN.
7. Press Enter to acknowledge.
8. Press Next; the following page appears:
Where *:**** **** can have the following values:
If the frequency pair showing is not the desired frequency pair:
9. Press Enter; the cursor (<) starts blinking.
10. Press the or key until the desired frequency pair shows.
11. Press Enter to acknowledge.
12. Press Next; the following page appears:
13. Press Enter; the cursor (<) starts blinking.
14. Using the numerical keys 0-9, enter the desired address code (0-63), i.e. the same address
code configured for the Mobile Station.
15. Press Enter to set the address code.
16. Press Next; the following page appears:
17. If AUTO RECOVERY (default ON) is to be set to OFF (not recommended): press Enter, press
the key to change ON to OFF and press Enter to confirm.
18. Press the key; the cursor points at the parameter CONF.PRTCTED (configuration
protection).
19. Press Enter if the change of settings by the counter station is allowed, then press the key
to change ON to OFF and press Enter again to confirm.
20. Press Next; the following page appears:
25