User's Guide
3 2
Loosen the nut to swivel the
bracket in the required direcon.
!
Tighten the nut with a spanner
to x the bracket’s posion.
Mounting
The mini-target can be used with or without a swivel bracket, as long as
it is mounted with its longest side vercal, and its carrying-handle at the
top.
To Mount the Target:
1. Hook the foot of the target underneath the knob on the boom of
the mounng plate. (See right).
2. Rotate the target backwards unl it is held in place by its magnets
against the mounng plate.
Knob
Mounng
Plate
Magnet
Swivel Bracket
Mounting on Horizontal Bar Mounting on Vertical Bar
Swivel Bracket
Swivel Bracket
The swivel bracket (Part № 21-0275-1) should be used to point
the target towards the RadaScan vessels’ working area.
It can be mounted on either a horizontal or vercal bar:
Positioning
The locaon, range and orientaon of the targets in relaon to the sensor have a signicant eect on the tracking
performance of the RadaScan / Mini-RadaScan systems, and hence on the quality of the posion data sent to the DP system.
RadaScan is a radar-based system. Metallic structures reect the microwave beam transmied by the sensor,
and can cause mulpath interference, where ghost images are reported by the system. However, this unwanted
phenomenon can be prevented by carefully posioning the targets according to the following guidelines:
Targets Should be Mounted:
With a clear, unobstructed view towards the RadaScan-equipped vessel.
At a height no lower than two metres below the vessel-mounted Sensor.
At a height no higher than ve metres above the vessel-mounted Sensor.
On outside corners of the rig or plaorm to minimise the amount of metallic structure around them.
Good Location
Good angle of incidence.
Lower angle of elevaon allows vessel
to pick up target on approach.
Longer range aids performance
in high sea states.
Usually clear of obstrucons
and away from enclosed corners.
Provides adequate cover
during vessel manœuvres.
Rig/Plaorm
RadaScan Vessel
Good Target
Locaons
Poor Location
Good angle of incidence.
Steep angle of elevaon prevents vessel from
picking up target on approach.
Shorter range inhibits performance
in high sea states.
Oen surrounded by obstrucons
and radar-reecng metalwork.
Does not provide adequate cover
during all vessel manœuvres.
Rig/Plaorm
RadaScan Vessel
Poor Target
Locaon
Targets Should NOT be Mounted:
On inside corners.
Below an overhang.