Operation Manual

Water level drops quickly. Locate the foot valve lower.
Clean the pump and replace worn parts.
Thermoswitch
switches the pump off.
Pump if overheated and switched off by the
thermal overloading protection.
Electric power missing.
Impurity particles (e.g. pebbles) have settled
down in the suction hole.
Let the device getting cool!
Disassamble and clean the pump, prevent suction of
foreign substances.
Inspection and Maintenance
With the exception of the below described cases, the pump shall be repaired in customer´s service.
Check the air pressure in the filling valve vessel (under the black lid) regularly (every 3 months) by means of a separate
device for pumping the tyres with manometer, as described below.
Pull out the network plug.
Open the appliance, watermain tap etc.
Modify the air pressure with separate device for pumping the tyres to 1,5 ± 0,3 bar.
Safety Instructions for Inspection and Maintenance
Before any maintenance works the connection with electric network shall be interrupted (by pulling the plug out of the
socket) and checked if the pump is not being put into operation.
Only device on which the maintenance is performed regularly and that is properly cared for can be good helper.
Defaults in maintenance and care for device can cause unpredictable accidents and injuries.
Plan of Inspection and Maintenance
Time interval Description Further details, if any
3 months Check the air pressure in the vessel 1,5 ± 0,3 bar