Operation Manual

Wrong
Wrong
Correct
The slag should not be removed before the weld gets cooled.
Continue welding of an interrupted weld after the slag is
removed.
Wrong
Correct
The welder should try to keep the arc length constant. As the
electrode gets worn, it should typically get nearer. It is
recommended to remove the electrode in the direction of the
weld to avoid forming a porous crater.
Signs on Unit
Meaning of symbols
Following symbols are used in this instruction/on the unit:
Product safety:
Product corresponds to
applicable EU standards
Prohibitions:
General ban combined with
another pictograph!
No pulling he cable!
Do not use in rain!
Warning:
Warning/Caution
Warning against dangerous
voltage
Commands:
Read operating manual
before use
Safety gloves to be used!
Wear protection shoes Welding helmet to be used
Wear protection clothing Unplug before opening
Environment protection:
Dispose waste
professionally so as not
harm the environment.
Packing cardboard material
may be delivered to collecting
centres for recycling.
Any defective and/or
disposed electric or
electronic devices must be
delivered to respective
collection centres.
Interseroh-Recycling system
with serial number
Package:
Protect against moisture!
Caution – Fragile!
This side up!
Technical specifications:
Manual arch welding with
coated electrodes
Mains protection
Voltage ~ frequency
Material recommended
thickness
IP 21 S
Protection type Weight
WARNING! Electric shock!
There is a risk of an injury
caused by electric shock!
Inhalation of welding fumes
can be hazardous to your
health
Sparks produced during
welding can cause explosion
or fire
Radiation from the electric arc
can damage the eyes and
cause skin injury
Electromagnetic fields can
interfere with the function of
pacemakers
10