Operation Manual
27
GB
ENGLISH
Failure removal
Failures Causes Removal
Engine does not start No power in the socket Check the fuse
Defective electric extension cable Pull the plug out, check it, replace it
Wrong connecting cable 5-wire connection at 2.5 mm
2
cross
section
Defective condenser switch Have the machine checked by a
professional electrician
Wrong engine rotation direction Wrong connection Use a screwdriver to turn the phase-
changing switch in the power supply
Splitting knife is not moving Adjust the two-hand control and
starting levers
Defective control valve - to be
replaced in a service centre only
Splitter has no power
Wrong rotation direction Have the rotation direction changed
by a professional
Few hydraulic oil Hydraulic oil to be added
Trigger is bent; hydraulic piston on
the valve is not fully seated
Check all screws on the trigger
Adjust the trigger so that the
hydraulic piston on the valve is fully
seated
Wood has many knobs and the
splitting knife is getting stuck
Lubricate the splitting knife
Control arm is bent Put the control arm back to the
starting position
The green supply button does not
hold after being pressed
Defective fuse, etc. Check the cable
2-phase running
Hydraulic pump is whistling, split-
ting knife running jerkily
Oil loss, bott
om contamination Tighten the screws replace the hose
Few hydraulic oil Hydraulic oil to be added