Datasheet
04/2019
mail@gude.info
www.gude.info
shop.gude.info
GUDE Systems GmbH
Von-der-Wettern-Str. 23
51149 Koeln
•
Germany
T
+49.221.912 90 97
F +49.221.912 90 98
12
2
Order Code Product Feature
7101 Temperature Sensor 7101 Cable sensor with splash-proof sensor head (IP64), RJ45 connector, -20°C to
+80°C, cable ca. 2.3 m
7104 * Temperature Sensor 7104 Cable sensor, RJ45 connector, -20°C to +80°C, cable ca. 2.3 m
7105 * Temp., Humidity Sensor 7105 Cable sensor, RJ45 connector, -20°C to +80°C, 0-90% humidity, cable ca. 2.3 m
7106 * Temp., Humidity, Air pressure Sensor
7106
Cable sensor, RJ45 connector, 20°C to +80°C, 0-90% humidity, 300-1100 hPa,
cable ca. 2.3 m
* Sensors also available with calibrated temperature range: 7104-2, 7105-2, 7106-2
7201 Temperature Sensor 7201 Box case with RJ45 socket, -20°C to +80°C
7202 Temp., Humidity Sensor 7202 Box case with RJ45 socket, -20°C to +80°C, 0-90% humidity
0804 IEC Extension Cable 0804 Extension cable for IEC C13 to C14, length: 3 m
0807 Cable Holder 0807 13 xation bridges for load cables at the rear side
Deployment of Expert Power Control 8226-1 by example of a data center
Expert Power Control 8226-1
with two sensors in 19 inch rack
The following data center scenario serves as an application
example for Expert Power Control 8226-1: A standard 19
inch rack with 12 servers is deployed with customer critical
applications running on the servers. The user‘s target: to
implement a reliable power distribution as well as an intel-
ligent device managment regarding capacitiy and system
monitoring - all at a reasonable cost-benefit ratio.
As for the extension of the IT infrastructure, typical objectives
arising are e.g.:
Enhancement of energy eciency
Metering of energy consumption on rack and server level
in real time
Implementation of a reliable environment monitoring
Prevention of down-times and of system critical
conditions
To ensure instant remote access in case of need
Support of commonly used authentification and
encryption protocols
Expert Power Control 8226-1 is mounted in a free RU space
of a 19 inch rack. Both IEC C20 power supplies (max. 16 A, 230
V) allow a total switching power of 7500 W for the servers.
Thanks to the integrated sensor interfaces, environment
monitoring is easily realized by connecting plug-and-play
sensors: Sensors 7104, 7105 and 7106 make it possible to
retrieve temperature, humidity and air pressure data from
dierent corners of the rack. Selectable threshold and repor-
ting settings enable users to dispose of relevant monitoring data for their power supply infrastructure. Hence,
appropriate actions can be taken before problems occur. Moreover integrated energy meters allow precise
measuring and logging of power consumption, both on unit and on outlet level.